Original Articles |
From the Translational Cardiac Electrophysiology Laboratory (Y.O., B.D.H., S.B.J., T.J.B., C.J.O., D.L.P.), Division of Cardiovascular Disease, Department of Internal Medicine, Health Sciences Research (D.O.H.), Mayo Clinic, Rochester, Minn.; and Biosense Webster (A.A., A.G.), Diamond Bar, Calif.
Correspondence to Douglas L. Packer, MD, 2-416 Alfred Building, Saint Marys Hospital Complex, Mayo Foundation, Rochester, MN 55902. E-mail packer.douglas{at}mayo.edu
Received September 18, 2007; accepted April 7, 2008.
Background— Multiple factors create discrepancies between electroanatomic maps and merged, preacquired computed tomographic images used in guiding atrial fibrillation ablation. Therefore, a Carto-based 3D ultrasound image system (Biosense Webster Inc) was validated in an animal model and tested in 15 atrial fibrillation patients.
Methods and Results— Twelve dogs underwent evaluation using a newly developed Carto-based 3D ultrasound system. After fiducial clip markers were percutaneously implanted at critical locations in each cardiac chamber, 3D ultrasound geometries, derived from a family of 2D intracardiac echocardiographic images, were constructed. Point-source error of 3D ultrasound-derived geometries, assessed by actual real-time 2D intracardiac echocardiographic clip sites, was 2.1±1.1 mm for atrial and 2.4±1.2 mm for ventricular sites. These errors were significantly less than the variance on CartoMerge computed tomographic images (atria: 3.3±1.6 mm; ventricles: 4.8±2.0 mm; P<0.001 for both). Target ablation at each clip, guided only by 3D ultrasound-derived geometry, resulted in lesions within 1.1±1.1 mm of the actual clips. Pulmonary vein ablation guided by 3D ultrasound-derived geometry resulted in circumferential ablative lesions. Mapping in 15 patients produced modestly smaller 3D ultrasound versus electroanatomic map left atrial volumes (98±24 cm3 versus 109±25 cm3, P<0.05). Three-dimensional ultrasound-guided pulmonary vein isolation and linear ablation in these patients were successfully performed with confirmation of pulmonary vein entrance/exit block.
Conclusions— These data demonstrate that 3D ultrasound images seamlessly yield anatomically accurate chamber geometries. Image volumes from the ultrasound system are more accurate than possible with CartoMerge computed tomographic imaging. This clinical study also demonstrates the initial feasibility of this guidance system for ablation in patients with atrial fibrillation.
Key Words: ablation mapping 3D ultrasound imaging
Related Articles
This article has been cited by other articles:
![]() |
E. M. Aliot, W. G. Stevenson, J. M. Almendral-Garrote, F. Bogun, C. H. Calkins, E. Delacretaz, P. D. Bella, G. Hindricks, P. Jais, M. E. Josephson, et al. EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias: Developed in a partnership with the European Heart Rhythm Association (EHRA), a Registered Branch of the European Society of Cardiology (ESC), and the Heart Rhythm Society (HRS); in collaboration with the American College of Cardiology (ACC) and the American Heart Association (AHA) Europace, June 1, 2009; 11(6): 771 - 817. [Full Text] [PDF] |
||||
![]() |
L. F. Tops and J. J. Bax The Year in Imaging Related to Electrophysiology J. Am. Coll. Cardiol. Img., April 1, 2009; 2(4): 498 - 510. [Full Text] [PDF] |
||||
![]() |
Z. M. Hijazi, K. Shivkumar, and D. J. Sahn Intracardiac Echocardiography During Interventional and Electrophysiological Cardiac Catheterization Circulation, February 3, 2009; 119(4): 587 - 596. [Full Text] [PDF] |
||||
|
Home | Subscriptions | Archives | Feedback | Authors | Help | Circulation Journals Home | AHA Journals Home | Search Copyright © 2008 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |