| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Original Articles |
From the Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands.
Correspondence to Martin J. Schalij, MD, PhD, Department of Cardiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, The Netherlands, PO Box 9600, 2300 RC Leiden, The Netherlands. E-mail m.j.schalij{at}lumc.nl
Received February 23, 2009; accepted July 22, 2009.
| Abstract |
|---|
|
|
|---|
Methods and Results— ICD patients (n=412, 361 men; age, 63±11 years) with ischemic heart disease and a left ventricular ejection fraction
40% were included. After device implantation, the occurrence of appropriate ICD therapy and mortality was noted. A survival analysis was performed comparing patients with a planar QRS-T angle
90° (n=124, 30%) with patients with a planar QRS-T angle >90° before device implantation. Furthermore, patients with a spatial QRS-T angle
100° (n=56, 14%) were compared with patients with a spatial QRS-T angle >100°, before implantation. For patients with a planar QRS-T angle >90° as compared with
90°, the adjusted hazard ratio for the occurrence of appropriate device therapy was 2.4 (95% CI, 1.1 to 5.2); a spatial QRS-T angle >100° was associated with an adjusted hazard ratio of 7.3 (95% CI, 1.0 to 53.8). Furthermore, a spatial QRS-T angle
100° exhibited a positive predictive value of 98% (95% CI, 95 to 100) for the prediction of an appropriate therapy-free follow-up.
Conclusions— A wide QRS-T angle is a strong predictor of appropriate device therapy in primary prevention ICD recipients with ischemic heart disease. Furthermore, a spatial QRS-T angle
100° might be of value in the identification of patients in whom, although currently indicated, ICD treatment should be reconsidered.
Key Words: implantable cardioverter-defibrillator electrocardiography ventricular arrhythmia primary prevention ischemic heart disease
| Introduction |
|---|
|
|
|---|
Clinical Perspective on p 548
Recently, a wide angle between the QRS and T axes, the QRS-T angle, on the standard 12-lead ECG was recognized as a novel and easy applicable marker of increased risk for cardiovascular mortality.20,21 Subsequently, a wide QRS-T angle was found to be associated with the increased incidence of appropriate device therapy and mortality in primary prevention ICD recipients with nonischemic cardiomyopathy.22 However, no data are available on the value of the QRS-T angle in ICD patients with IHD.
The aim of the current study was to assess the value of the QRS-T angle in predicting life-threatening ventricular arrhythmias in primary prevention ICD patients with IHD. Furthermore, the value of the QRS-T angle was evaluated as a parameter to identify patients at low risk for ventricular arrhythmias.
| Methods |
|---|
|
|
|---|
During follow-up, the occurrence of appropriate ICD therapy and patient mortality was noted. In addition, for the purpose of this study, the ECG made before implantation was analyzed.
ICD Implantation and Follow-Up
All defibrillator systems were implanted transvenously without thoracotomy. Device follow-up was scheduled every 3 to 6 months. All printouts were carefully checked for appropriate and inappropriate ICD therapy. In the case of any ICD therapy, an electrophysiologist, blinded to QRS-T measurements, determined whether or not the ICD therapy was appropriate. All therapies, either antitachycardia pacing (ATP) or shock, were classified as appropriate when they occurred in response to life-threatening arrhythmias (ventricular tachycardia or ventricular fibrillation) and as inappropriate when triggered by sinus or supraventricular tachycardia, T-wave oversensing, or electrode dysfunction.
Defibrillators were programmed as follows: ventricular arrhythmia faster than 150 bpm was monitored by the device without consequent defibrillator therapy. Ventricular arrhythmias faster than 188 bpm were initially attempted to be terminated with 2 bursts of ATP and, after continuation of the arrhythmia, with defibrillator shocks. In the case of a ventricular arrhythmia faster than 210 bpm, device shocks were the initial therapy. Furthermore, atrial arrhythmia detection was set to >170 bpm with supraventricular tachycardia discriminators enabled. Settings were adapted only when clinically indicated (ie, hemodynamically well-tolerated ventricular tachycardia at high rate; ventricular tachycardia in the monitor zone).
ECG Analysis
First, the quality of ECGs was evaluated. If electrode displacement, missing leads, or signal noise was present, the ECGs were excluded from the analysis. Because right ventricular pacing alters normal cardiac conduction and results, by definition, in an abnormal QRS-T angle, patients with a pacemaker were excluded from the analysis.25 Subsequently, the ECGs were analyzed with a dedicated computer program (LEADS, Leiden ECG Analysis and Decomposition Software).26 Full details on the computation method and LEADS based values of vector characteristics in healthy subjects have been extensively described earlier.27 In short, the software converts the standard ECG into a vectorcardiogram and computes the 3D orientation of the QRS- and T-axes. Thereafter, the QRS-T angle is calculated in the plane formed by the QRS- and T-axes, the spatial QRS-T angle. In addition, the more commonly used but less precise projection of the spatial QRS-T angle in the frontal plane, the planar QRS-T angle, was computed. Previous studies demonstrated that a spatial QRS-T angle wider than 100° is associated with the presence of cardiac disease and increased cardiovascular mortality.20,21 Pavri et al22 recently demonstrated that a planar QRS-T angle wider than 90° is associated with an increased incidence of appropriate device shocks and mortality. In the present study, these cutoffs (100° for the spatial and 90° for the planar QRS-T angle) were applied.
Statistical Analysis
A survival analysis comprising of the following end points was performed (1) first appropriate ICD therapy (ATP and/or shock); (2) all-cause mortality; and (3) a composite end point of all-cause mortality and first appropriate device therapy, whichever occurred first. ICD recipients with a narrow QRS-T angle were compared with those with a wide QRS-T angle. The points of cutoff were predefined as described above, 100° for the spatial and 90° for the planar QRS-T angle. Cumulative event rates of end points were analyzed by the method of Kaplan–Meier. Relationships between baseline parameters and end points were assessed with Cox proportional hazard regression analysis. For the composite end point, survival time was defined as time to all-cause death or appropriate device therapy, whichever occurred first. For each variable, a hazard ratio (HR) with a 95% CI was calculated. Therapy-free follow-up was defined as a study follow-up without the occurrence of appropriate ICD therapy.
Continuous data are expressed as mean±SD or median and quartiles where appropriate; dichotomous data are presented as numbers and percentages. Comparison of data at baseline was performed with the Student t test for unpaired data and
2 tests with Yates correction when appropriate.
| Results |
|---|
|
|
|---|
40% underwent ICD implantation for primary prevention of sudden cardiac death in the Leiden University Medical Center. Thirty-two (7%) patients were excluded because of the presence of a pacemaker and 16 (3%) patients were excluded because their ECG before device implantation could not be analyzed because of technical reasons such as electrode displacement, missing leads, or signal noise. The remaining 412 (90%) ICD recipients (63±11 years, 88% men) were included in the analysis and were followed for 22±17 months (range, 0 to 77 months). Baseline characteristics are summarized in Table 1.
|
QRS-T Angle and All-Cause Mortality
In 124 (30%) patients, a planar QRS-T angle smaller or equal to 90° was measured on the baseline ECG. As summarized in Table 1, patients with a narrow planar QRS-T angle were more likely to be younger (61±11 year versus 64±10 years, P<0.05), to have a better LVEF (28±7% versus 25±7%, P<0.001), and shorter QRS duration (120±29 ms versus 134±34 ms, P<0.001). The HR of a planar QRS-T angle >90° for mortality was 3.1 (95% CI, 1.3 to 7.3) as compared with patients with a narrow planar QRS-T angle. The cumulative event-free follow-up for all-cause mortality in patients with a narrow planar QRS-T angle was 99% (95% CI, 98 to 100) at 1 year, 92% (95% CI, 87 to 98) at 2 years, and 92% (95% CI, 87 to 98) at 4 years of follow-up (Figure 1).
|
|
|
Identification of Patients Free of Life-Threatening Arrhythmias
Evaluation of the usefulness of a planar QRS-T angle
90° at baseline in the prediction of an appropriate therapy-free follow-up revealed a positive predictive value of 94% (95% CI, 89 to 98) and a negative predictive value of 17% (95% CI, 12 to 21).
The spatial QRS-T angle had a positive predictive value of 98% (95% CI, 95 to 100) and a negative predictive value of 15% (95% CI, 12 to 19) for the prediction of an appropriate therapy-free follow-up. Most importantly, only 2% of the patients with a spatial QRS-T angle
100° had appropriate device discharges during follow-up, the only event occurring after 745 days (Figure 2).
| Discussion |
|---|
|
|
|---|
100° before implantation, exhibited an absolute risk of 2% for appropriate therapy during follow-up. With primary prevention ICD therapy as a class I indication in international guidelines in patients with a low LVEF, the indicated population, and therefore the worldwide defibrillator implantation rates, has increased significantly.11,12 This expansion is of such magnitude that health care systems might lack the logistic capacity and financial means to meet the demand of ICD implantations.16,28 Furthermore, MADIT II demonstrated a cumulative incidence of the need for defibrillator backup of only 35% of patients after 3 years.13 Moreover, 6% of ICD-treated patients have severe device-related adverse events.14 These issues underscore the need for better risk stratification within the indicated population.
Ideally, a parameter for the identification of a population at high or at low risk for the need for defibrillator backup should be noninvasive and easily acquired. An ECG-derived parameter such as the QRS-T angle, validated in the current analysis, would fit these demands.
Risk Stratification With the QRS-T Angle
The QRS-T angle is the angle between the electric axes of depolarization and repolarization. In the present study, clinical application of both the planar as well as the spatial QRS-T angle has been investigated in primary prevention ICD recipients with ischemic heart disease. The planar QRS-T angle is the projection of the spatial QRS-T angle in the frontal plane. As with any projection, it is sensitive to variations of the anatomic position of the heart in thorax. Therefore, the spatial QRS-T angle, which is calculated in the plane that the QRS- and T-axes form, is a more robust clinical tool. This is an important issue because the results from this study demonstrate that a narrow spatial angle is associated with a lower risk of ventricular arrhythmias. Although the spatial QRS-T angle cannot be derived directly from the surface ECG, recent studies have provided easy methods to acquire the spatial QRS-T angle from the standard 12-lead ECG.29
In our population of ischemic primary prevention ICD recipients, patients with a wide planar QRS-T angle demonstrated a HR of 2.5 for the need of defibrillator backup and 3.1 for all-cause mortality. In the recently published post hoc analysis of the DEFINITE trial by Pavri et al,22 the planar QRS-T angle was analyzed as a predictor of the composite end point of appropriate device therapy, mortality, and resuscitated cardiac arrest in a population with nonischemic cardiomyopathy. In this study, the HR of a planar QRS-T angle wider than 90° for the occurrence of appropriate device therapy was 1.95 (95% CI, 1.24 to 3.08). The HR for all-cause mortality was 1.81 (95% CI, 1.04 to 3.13).
After adjustment for other commonly used risk factors, the presence of a spatial QRS-T angle wider than 100° was associated with an HR of 7.3 for the occurrence of device therapy for ventricular arrhythmias as compared with patients with a spatial QRS-T angle
100°, in our population. More importantly, all patients with a spatial QRS-T angle
100° were free of device-generated therapy during 2 years after implantation. This indicates that the spatial QRS-T angle may have an important potential for risk stratification in patients with ischemic heart disease.
Previous studies on the spatial QRS-T angle have already indicated its high value in the risk stratification for cardiac death in a population without ICDs.20,21 In a large cohort of patients, Yamazaki et al21 observed an HR of 1.9 (95% CI, 1.7 to 2.1) on cardiovascular death for a spatial QRS-T angle >100° after correction for other ECG parameters.
As a consequence of the balanced regulation of electric activation and recovery of the ventricles, a narrow QRS-T angle is generally observed in healthy individuals.27 Ventricular scar or residual ischemia, which is the arrhythmic substrate in ischemic cardiomyopathy, causes an imbalance of this process, sometimes referred to as electric heterogeneity or discordance of depolarization and repolarization.30 Vectorcardiographically, these alterations in cardiac electrophysiology become, among others, apparent through directional changes of the QRS and T vectors and consequent widening of the QRS-T angle. When patients with ischemic cardiomyopathy have a narrow QRS-T angle, which is then associated with electric homogeneity, it could be postulated that the amount of arrhythmic substrate is limited and may even be absent. The high incidence of ventricular arrhythmias in patients with a wide QRS-T angle and the low incidence in patients with a narrow QRS-T angle, as observed in the current study, underscores this principle.
Clinical Implications
Several noninvasive parameters that could improve patient selection for ICD therapy have been proposed. These include LVEF, QRS duration, QT interval, heart rate variability, ventricular ectopy on ambulatory monitoring, exercise capacity, and T-wave alternans.31 In addition, total cosine R to T, which is also a measure of QRS-T concordance like the QRS-T angle, has been proven a promising parameter in the mortality risk stratification in patients after myocardial infarction.32,33 However, this variable has not been assessed in an ICD-treated population, to our knowledge. Although the majority of these parameters appear promising, only LVEF has proven its usefulness in patient selection for ICD implantation and is currently the most important factor in the clinicians choice whether or not an ICD is indicated.11 Still, in the implanted ischemic population, identified as being at high risk for ventricular arrhythmia based on depressed LVEF, 35% of patients actually have appropriate device therapy during follow-up, prompting the identification of a subpopulation at low risk.13 In our population of ischemic primary prevention ICD recipients, patients with a spatial QRS-T angle
100° demonstrated no ventricular arrhythmias during the first 2 years after implantation and only 2% during further follow-up. These results imply that this parameter could be used in the discrimination of patients in whom the beneficial effects of an ICD might not exceed the costs and potential morbidity accompanying ICD therapy.
Limitations
This was a nonrandomized, prospective, observational study, performed to assess the long-term follow-up in ischemic primary prevention ICD recipients and to assess the value of the planar and spatial QRS-T angle in baseline risk stratification. Adjustment for additional variables in the multivariable Cox model was limited by the number of end points reached. Furthermore, some patients without therapy during study follow-up might have reached an end point, had follow-up been longer. Additionally, because not all patients had postmortem ICD interrogation, some cases of death might have been arrhythmic. Finally, because patients were included over a period of 11 years, expanding guidelines for the implantation of defibrillators, treatment of acute myocardial infarction, and pharmacological antiarrhythmic therapy could have created an inhomogeneous population.
| Conclusion |
|---|
|
|
|---|
100° on the ECG before implantation can identify patients with very low risk of life-threatening ventricular arrhythmias in whom the beneficial effect of ICD treatment might not exceed the costs and potential complications. | Acknowledgments |
|---|
Dr Bax received research grants from GE Healthcare, BMS Medical Imaging, Edwards Lifesciences, Boston Scientific, Medtronic, Biotronik, and St Jude. Dr Schalij received research grants from Biotronik, Medtronic, and Boston Scientific.
| References |
|---|
|
|
|---|
2. Josephson M, Wellens HJ. Implantable defibrillators and sudden cardiac death. Circulation. 2004; 109: 2685–2691.
3. Zipes DP, Wellens HJ. Sudden cardiac death. Circulation. 1998; 98: 2334–2351.
4. Risk stratification and survival after myocardial infarction. N Engl J Med. 1983; 309: 331–336.[Abstract]
5. Rouleau JL, Talajic M, Sussex B, Potvin L, Warnica W, Davies RF, Gardner M, Stewart D, Plante S, Dupuis R, Lauzon C, Ferguson J, Mikes E, Balnozan V, Savard P. Myocardial infarction patients in the 1990s: their risk factors, stratification and survival in Canada: the Canadian Assessment of Myocardial Infarction (CAMI) Study. J Am Coll Cardiol. 1996; 27: 1119–1127.[Abstract]
6. Bardy GH, Lee KL, Mark DB, Poole JE, Packer DL, Boineau R, Domanski M, Troutman C, Anderson J, Johnson G, McNulty SE, Clapp-Channing N, Vidson-Ray LD, Fraulo ES, Fishbein DP, Luceri RM, Ip JH. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med. 2005; 352: 225–237.
7. Bristow MR, Saxon LA, Boehmer J, Krueger S, Kass DA, De MT, Carson P, DiCarlo L, DeMets D, White BG, DeVries DW, Feldman AM. Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med. 2004; 350: 2140–2150.
8. Buxton AE, Lee KL, Fisher JD, Josephson ME, Prystowsky EN, Hafley G. A randomized study of the prevention of sudden death in patients with coronary artery disease: Multicenter Unsustained Tachycardia Trial Investigators. N Engl J Med. 1999; 341: 1882–1890.
9. Moss AJ, Hall WJ, Cannom DS, Daubert JP, Higgins SL, Klein H, Levine JH, Saksena S, Waldo AL, Wilber D, Brown MW, Heo M. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia: Multicenter Automatic Defibrillator Implantation Trial Investigators. N Engl J Med. 1996; 335: 1933–1940.
10. Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, Daubert JP, Higgins SL, Brown MW, Andrews ML. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002; 346: 877–883.
11. Epstein AE, DiMarco JP, Ellenbogen KA, Estes NA III, Freedman RA, Gettes LS, Gillinov AM, Gregoratos G, Hammill SC, Hayes DL, Hlatky MA, Newby LK, Page RL, Schoenfeld MH, Silka MJ, Stevenson LW, Sweeney MO, Smith SC Jr, Jacobs AK, Adams CD, Anderson JL, Buller CE, Creager MA, Ettinger SM, Faxon DP, Halperin JL, Hiratzka LF, Hunt SA, Krumholz HM, Kushner FG, Lytle BW, Nishimura RA, Ornato JP, Page RL, Riegel B, Tarkington LG, Yancy CW. ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices): developed in collaboration with the Am Association for Thoracic Surgery and Society of Thoracic Surgeons. Circulation. 2008; 117: e350–e408.
12. Maisel WH, Moynahan M, Zuckerman BD, Gross TP, Tovar OH, Tillman DB, Schultz DB. Pacemaker and ICD generator malfunctions: analysis of Food and Drug Administration annual reports. JAMA. 2006; 295: 1901–1906.
13. Moss AJ, Greenberg H, Case RB, Zareba W, Hall WJ, Brown MW, Daubert JP, McNitt S, Andrews ML, Elkin AD. Long-term clinical course of patients after termination of ventricular tachyarrhythmia by an implanted defibrillator. Circulation. 2004; 110: 3760–3765.
14. Rosenqvist M, Beyer T, Block M, den DK, Minten J, Lindemans F. Adverse events with transvenous implantable cardioverter-defibrillators: a prospective multicenter study: European 7219 Jewel ICD Investigators. Circulation. 1998; 98: 663–670.
15. Sweeney MO, Wathen MS, Volosin K, Abdalla I, DeGroot PJ, Otterness MF, Stark AJ. Appropriate and inappropriate ventricular therapies, quality of life, and mortality among primary and secondary prevention implantable cardioverter defibrillator patients: results from the Pacing Fast VT REduces Shock ThErapies (PainFREE Rx II) trial. Circulation. 2005; 111: 2898–2905.
16. Tung R, Zimetbaum P, Josephson ME. A critical appraisal of implantable cardioverter-defibrillator therapy for the prevention of sudden cardiac death. J Am Coll Cardiol. 2008; 52: 1111–1121.
17. Brodine WN, Tung RT, Lee JK, Hockstad ES, Moss AJ, Zareba W, Hall WJ, Andrews M, McNitt S, Daubert JP. Effects of beta-blockers on implantable cardioverter defibrillator therapy and survival in the patients with ischemic cardiomyopathy (from the Multicenter Automatic Defibrillator Implantation Trial-II). Am J Cardiol. 2005; 96: 691–695.[CrossRef][Medline]
18. Goldenberg I, Moss AJ, McNitt S, Zareba W, Daubert JP, Hall WJ, Andrews ML. Cigarette smoking and the risk of supraventricular and ventricular tachyarrhythmias in high-risk cardiac patients with implantable cardioverter defibrillators. J Cardiovasc Electrophysiol. 2006; 17: 931–936.[CrossRef][Medline]
19. Pietrasik G, Goldenberg I, McNitt S, Moss AJ, Zareba W. Obesity as a risk factor for sustained ventricular tachyarrhythmias in MADIT II patients. J Cardiovasc Electrophysiol. 2007; 18: 181–184.[CrossRef][Medline]
20. Kardys I, Kors JA, van dM I, Hofman A, van der Kuip DA, Witteman JC. Spatial QRS-T angle predicts cardiac death in a general population. Eur Heart J. 2003; 24: 1357–1364.
21. Yamazaki T, Froelicher VF, Myers J, Chun S, Wang P. Spatial QRS-T angle predicts cardiac death in a clinical population. Heart Rhythm. 2005; 2: 73–78.[CrossRef][Medline]
22. Pavri BB, Hillis MB, Subacius H, Brumberg GE, Schaechter A, Levine JH, Kadish A. Prognostic value and temporal behavior of the planar QRS-T angle in patients with nonischemic cardiomyopathy. Circulation. 2008; 117: 3181–3186.
23. van der Velde ET, Atsma DE, Schalij MJ, Witteman JC, Fogel RI, de Bruijn FDB. Development and implementation of a fully paperless cardiology information system (EPD-Vision). Comput Cardiol. 2006; 33: 849–852.
24. van der Burg AE, Bax JJ, Boersma E, van EL, Bootsma M, van der Wall EE, Schalij MJ. Standardized screening and treatment of patients with life-threatening arrhythmias: the Leiden out-of-hospital cardiac arrest evaluation study. Heart Rhythm. 2004; 1: 51–57.[CrossRef][Medline]
25. van Huysduynen BH, Swenne CA, Bax JJ, Bleeker GB, Draisma HH, van EL, Molhoek SG, van d V, van der Wall EE, Schalij MJ. Dispersion of repolarization in cardiac resynchronization therapy. Heart Rhythm. 2005; 2: 1286–1293.[CrossRef][Medline]
26. Draisma HHM, Swenne CA, van de Vooren H, Maan AC, van Huysduynen BH, van der Wall EE, Schalij MJ. LEADS: an Interactive Research Oriented ECG/VCG Analysis System. Comput Cardiol. 2005; 32: 515–518.
27. Scherptong RW, Henkens IR, Man SC, Le CS, Vliegen HW, Draisma HH, Maan AC, Schalij MJ, Swenne CA. Normal limits of the spatial QRS-T angle and ventricular gradient in 12-lead electrocardiograms of young adults: dependence on sex and heart rate. J Electrocardiol. 2008; 41: 648–655.[CrossRef][Medline]
28. Borleffs CJ, Wilde AA, Cramer MJ, Wever E, Mosterd A. Clinical implementation of guidelines for cardioverter defibrillator implantation: lost in translation? Neth Heart J. 2007; 15: 129–132.[Medline]
29. Rautaharju PM, Prineas RJ, Zhang ZM. A simple procedure for estimation of the spatial QRS/T angle from the standard 12-lead electrocardiogram. J Electrocardiol. 2007; 40: 300–304.[CrossRef][Medline]
30. Draisma HH, Schalij MJ, van der Wall EE, Swenne CA. Elucidation of the spatial ventricular gradient and its link with dispersion of repolarization. Heart Rhythm. 2006; 3: 1092–1099.[CrossRef][Medline]
31. Goldberger JJ, Cain ME, Hohnloser SH, Kadish AH, Knight BP, Lauer MS, Maron BJ, Page RL, Passman RS, Siscovick D, Siscovick D, Stevenson WG, Zipes DP. American Heart Association/American College of Cardiology Foundation/Heart Rhythm Society scientific statement on noninvasive risk stratification techniques for identifying patients at risk for sudden cardiac death: a scientific statement from the American Heart Association Council on Clinical Cardiology Committee on Electrocardiography and Arrhythmias and Council on Epidemiology and Prevention. Circulation. 2008; 118: 1497–1518.
32. Perkiomaki JS, Hyytinen-Oinas M, Karsikas M, Seppanen T, Hnatkova K, Malik M, Huikuri HV. Usefulness of T-wave loop and QRS complex loop to predict mortality after acute myocardial infarction. Am J Cardiol. 2006; 97: 353–360.[CrossRef][Medline]
33. Zabel M, Acar B, Klingenheben T, Franz MR, Hohnloser SH, Malik M. Analysis of 12-lead T-wave morphology for risk stratification after myocardial infarction. Circulation. 2000; 102: 1252–1257.
| Footnotes |
|---|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Home | Subscriptions | Archives | Feedback | Authors | Help | Circulation Journals Home | AHA Journals Home | Search Copyright © 2009 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |