Original Articles |
From the Hôpital Cardiologique du Haut-Lévêque and the Université Victor Segalen Bordeaux II, Bordeaux, France.
Correspondence to Sébastien Knecht, MD, Service de Rythmologie, Hôpital Cardiologique du Haut-Lévêque, Avenue de Magellan, 33604 Bordeaux-Pessac, France. E-mail sebastien.knecht{at}chu-brugmann.be
Received April 22, 2008; accepted June 3, 2008.
Background— Transseptal puncture with a conventional mechanical technique can fail because of a resistant interatrial septum. We evaluated the efficacy and safety of a new method to cross-resistant septae by transmitting radiofrequency (RF) energy through the transseptal needle.
Methods and Results— Among 269 consecutive transseptal punctures, 13 (5%) were unsuccessful in 12 different patients (11 men aged 52±12 years) using the conventional Brockenbrough technique. All 12 patients had previously undergone at least 1 transseptal catheterization. The needle position in relation to the fossa ovalis was assessed by fluoroscopy in orthogonal views and was confirmed with contrast injection and by visualizing the characteristic "tenting" of the fossa ovalis. Before using RF energy, there were a median of 6 unsuccessful attempts to perforate the septum conventionally, with 1 pericardial puncture (with a nonsignificant effusion). RF transseptal puncture was then performed by delivering unipolar RF with manual contact between the ablation catheter and the proximal extremity of the needle at the patients groin. RF transseptal puncture was achieved at the first attempt in all patients within a median of 1 second (interquartile range, 1 to 4) and without any complication. The only parameter predictive of a septum resistant to conventional puncture was the total number of transseptal catheterizations (3.2±1 versus 1.8±1, P<0.001).
Conclusion— Transmission of RF energy from the ablation catheter up to the tip of the transseptal needle provides an easy and safe method for piercing the fossa ovalis when the conventional approach fails because of a resistant septum.
Key Words: transseptal puncture left atrium access radiofrequency atrial fibrillation resistant septum
Related Article
This article has been cited by other articles:
![]() |
S. S. Kim, Z. M. Hijazi, R. M. Lang, and B. P. Knight The use of intracardiac echocardiography and other intracardiac imaging tools to guide noncoronary cardiac interventions. J. Am. Coll. Cardiol., June 9, 2009; 53(23): 2117 - 2128. [Abstract] [Full Text] [PDF] |
||||
|
Home | Subscriptions | Archives | Feedback | Authors | Help | Circulation Journals Home | AHA Journals Home | Search Copyright © 2008 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |